Mills & Nebraska Architectural Products
    Orlando Health Dr. P. Phillips Hospital entrance drive and patient towers in Orlando, Florida

    Industries we serve

    Healthcare & Medical

    Mills & Nebraska supplies hospitals, clinics and medical office buildings in Florida with fire-rated hollow metal doors, welded frames, lead-lined doors and access-control hardware that meet NFPA 80, NFPA 101 and the ADA 2010 Standards. Fire-rated assemblies can be labeled in-house through our Intertek-certified labeling program.

    Years in business
    90+
    Openings secured
    1M+
    Years of staff experience
    1K+
    On stocked items
    Same Day

    Overview

    Door and hardware solutions for healthcare facilities

    Healthcare facilities demand high standards of safety, hygiene and accessibility. From operating rooms that need hermetic seals to patient corridors and stair enclosures that need smoke and fire protection, Mills & Nebraska supplies door, frame and hardware assemblies that support NFPA 80, NFPA 101, ADA and Joint Commission requirements.

    Requirements

    What healthcare openings require

    1. 01

      Labeled fire-rated doors and frames for stairs, shafts and hazardous areas per NFPA 80

    2. 02

      Patient room corridor doors that resist smoke and latch positively per NFPA 101

    3. 03

      Lead-lined doors and frames for imaging and radiation treatment rooms

    4. 04

      Hermetic sliding doors for operating suites and clean rooms

    5. 05

      ADA-compliant hardware with hands-free and access-control options

    6. 06

      Antimicrobial finish options and gasketed assemblies for isolation rooms

    FAQs

    Healthcare door FAQs

    Have a question about a specific opening? Call (866) 304-DOOR (3667)

    What fire rating do hospital stair doors need in Florida?

    Stair door ratings follow the enclosure wall. A 2-hour stair enclosure needs 90-minute doors, and a 1-hour enclosure needs 60-minute doors. The Florida Building Code 8th Edition (2023) and NFPA 101 set the enclosure rating, and NFPA 80 governs how the labeled door, frame and hardware are installed and maintained.

    Do patient room corridor doors have to be fire-rated?

    In new health care occupancies, NFPA 101 generally does not require patient room corridor doors to carry a fire rating, but they must resist the passage of smoke and have positive latching hardware. Doors in required smoke barriers, fire barriers and hazardous areas have separate requirements, so the door schedule should follow the approved life safety plan.

    How often must hospital fire and smoke doors be inspected?

    NFPA 80 requires fire door assemblies to be inspected and tested at least annually, and NFPA 105 sets a similar annual inspection for smoke door assemblies. Written inspection records are kept for the authority having jurisdiction and are reviewed during Joint Commission surveys.

    Get a quote for your healthcare project

    Send us your drawings or door schedule. With 90+ years in business and in-house Design and Specification Services, our team responds within 24 business hours with lead times, submittals and Florida code requirements.